DEHUMIDIFICATION AND ICERING Systems
Airdom pressure support, heating and cooling system
Pressure support system is designed to keep Airdome under pressure of 250Pa. Heating system designed for Airdome heating to 10C at outside temperature -30C with distric water 110/40C.
Cooling system is used in summer to keep temperature at 25C.
Russia (Moscow)
2020
Ice hall
The heating system is made with gas/oil heater burner with modulating regulation to keep the airdome at 10C.
The cooling system is designed to keep the temperature in Airdome at 30C and 40% humidity at outside temperature 40C.
Austria (Vienna)
2011